¿­·¢¡¤k8¹ú¼Ê,¿­·¢¹ÙÍø

±¾Ò³°üº¬
MM-241898-GWA-Load-Management-e-Mobility-2000x2000.jpg

µç¶¯Æû³µÐÐÒµ- ¿­·¢¡¤k8¹ú¼Ê,¿­·¢¹ÙÍø¸ºÔعÜÀí½â¾ö·½°¸

×÷ΪÄÜÔ´ºÍ¶¯Á¦×ªÐ͵ÄÒ»²¿·Ö£¬µç¶¯Æû³µ (EV) ³äµçÕ¾±äµÃÓÈΪÖØÒª¡£ÖÇÄܳäµçÕ¾µÄ²¼¾ÖºÍ¸ºÔعÜÀíÊǵçÍøÔËÓªÉÌ¡¢ÉèÊ©¹ÜÀíÈËÔ±ºÍ¹¤Òµ¹«Ë¾À©´óµç¶¯Æû³µÊг¡µÄÖ÷ÒªÌôÕ½¡£

Ôڵ綯Æû³µ³äµç»ù´¡ÉèÊ©ÁìÓò£¬¿­·¢¡¤k8¹ú¼Ê,¿­·¢¹ÙÍøÌṩÁËÁ¬½ÓºÍ¿ØÖÆÄÜÁ¿Á÷µÄ¶¨Öƽâ¾ö·½°¸¡£

³äµç»ù´¡ÉèÊ©µÄ¶¨ÖÆ»¯µçÍø¼¯³ÉºÍ¹ÜÀí

Ëæ×ŵç×Ó³äµçÕ¾µÄ±¬·¢Ê½Ôö³¤£¬ÎÞÂÛÊǹ«¹²»¹ÊÇ˽È˳äµçÕ¾£¬µç¶¯Æû³µ³äµç»ù´¡ÉèÊ©µÄµçÍø¼¯³ÉºÍ¹ÜÀíʼÖÕÊÇÒ»¸öÄÑÌ⡣ΪÁË·ÀÖ¹µçÍø¹ýÔØ£¬ÐèÒªÒ»¸ö³äµçºÍ¸ºÔعÜÀíϵͳÀ´¿ØÖÆÄÜÁ¿Á÷¡£

¿­·¢¡¤k8¹ú¼Ê,¿­·¢¹ÙÍøÁé»î¡¢ÃæÏòδÀ´µÄ¸ºÔعÜÀí½â¾ö·½°¸Ê¹µç¶¯Æû³µ³äµçÉèÊ©µÄµçÍø¼¯³ÉºÍ¹ÜÀí±äµÃ¾­¼Ã¿É¿Ø¡£
Ìض¨ÐÐÒµºÍ¼¼ÊõÇ°¾°£ºÔÚÒ»¸ö¿ØÖÆÆ÷Éϼ´¿É½øÐеçÍø¼ÆËãºÍ¸ºÔعÜÀí£¬ÒÔ¼°ÏÖÓеÄÔÚ¹¤Òµ¡¢½¨ÖþºÍÄÜÔ´»·¾³ÖеÄÓ¦Óýâ¾ö·½°¸¡£

ÓÅÊÆÒ»ÀÀ£º

  •  ¶àÖÖЭÒéºÍ½Ó¿Ú£¬¶ÀÁ¢ÓëÖÆÔìÉ̺͸ºÔØ£¬Í¨ÓÃÐÔÇ¿

  • ¶¯Ì¬¡¢Ä£¿é»¯µÄÓ²¼þÉè¼Æ£¬·á¸»µÄ×Ô¶¯»¯ºÍÁ¬½Ó¼¼Êõ²úÆ·ÒÔ¼°½Ó¿Úµç×Ó²úÆ·

  • ÐÐÒµ¾­Ñé·á¸»£ºÔøΪ¶à¸ö³äµçÕ¾ÖÆÔìÉÌÌṩ½â¾ö·½°¸¡¢²¢ÎªÏîÄ¿¹æ»®ºÍʵʩÌṩרҵ¼¼ÊõÖ§³Ö

  • ·ÀÖ¹·åÖµ¸ºÔØ

×î´óÏ޶ȵØÌá¸ß³äµç»ù´¡ÉèÊ©ÀûÓÃÂÊ

¶¯Ì¬¼°¾²Ì¬¸ºÔعÜÀí

ÆäÖصãÊÇÓë±ê×¼±ÚºÐºÍ³äµçÕ¾¡¢¾ßÓÐModbus?¹¦ÄܵÄÒDZíºÍ¾ßÓÐDocker?¹¦ÄܵĿØÖÆÆ÷µÄ¼æÈÝÐԺͻ¥²Ù×÷ÐÔ¡£ÀýÈ磬¿­·¢¡¤k8¹ú¼Ê,¿­·¢¹ÙÍøÓ¦ÓøºÔعÜÀí¿ÉÓÃÓÚ¹ÜÀíÈÎÒâ¹æÄ£µÄ³äµç³¡£¬»ò¼¯³É¶àÖÖ¸ºÔØ£¬²¢ÒÔ±ÜÃâ·åÖµ¸ºÔصķ½Ê½¶ÔÆä½øÐпØÖÆ¡£ÐµÄÔ­ÉúMQTT½Ó¿ÚÖ§³ÖÁ¬½Óµ½¿­·¢¡¤k8¹ú¼Ê,¿­·¢¹ÙÍø½â¾ö·½°¸Æ½Ì¨»òÆäËû»ùÓÚÔƵÄƽ̨¡£½èÖú¿­·¢¡¤k8¹ú¼Ê,¿­·¢¹ÙÍøÓ¦Óÿͻ§±äµçÕ¾µÄ±ê×¼½Ó¿Ú£¬¿ÉÒÔ¸ù¾ÝÍøÂçÔËÓªÉ̵ļ¼ÊõÁ¬½Ó¹æÔò(TCR)¶Ô»ìºÏ³äµç³¡µÄEEGϵͳ½øÐпÉÅäÖÃÁ¬½Ó¡£

  • ÓÅ»¯ÀûÓóäµç»ù´¡ÉèÊ©
  • ¶¯Ì¬¿ØÖÆÌṩ±È¿ÉÓõçÍøÁ¬½Ó¹¦Âʸü¸ßµÄ³äµçµã¹¦ÂÊ¡£
  • ½Ó¿ÚºÍÆ·ÅƵĿª·ÅÐÔ

Èí¼þ¸ÅÀÀ

¿­·¢¡¤k8¹ú¼Ê,¿­·¢¹ÙÍøÓ¦ÓøºÔعÜÀíµÄÓÅÊÆ

AC/DC³äµç³¡

  • ÊÊÓÃÓÚСÐÍ¡¢ÖÐÐÍ»ò´óÐͳäµç³¡
  • ÿ¸ö¿ØÖÆÆ÷1µ½225¸ö³äµçµã
  • ¿ìËÙ×°ÔØ»ú¡¢³äµçÕ¾ºÍ±ÚºÐµÄ×éºÏ
  • ×ۺϳäµçÕ¾µÄ¹¦ÂÊ£º11ǧÍßµ½350ǧÍß
  • »ìºÏʽ³äµç³¡£º½«½»Á÷³äµçÆ÷ºÍÖ±Á÷³äµçÆ÷×éºÏÔÚÒ»Æð

¶ÀÁ¢¿ØÖÆ

  • ¸ù¾Ý³äµçµã¡¢³äµç×é»òÕû¸ö³äµç³¡½øÐпØÖÆ
  • ½«³äµçµãºÏ²¢µ½³äµç×é
  • ¸ù¾ÝÁ¬½Ó¹¦ÂʶԵçÆø»ù´¡ÉèÊ©½øÐе¥¶Àµ÷Õû
  • È·¶¨²»Í¬³äµçµãºÍ³äµç×éµÄÓÅÏȼ¶

¼¯³ÉÓÃÓÚ¹â·ü·¢µçºÍ´æ´¢ÏµÍ³µÄÄæ±äÆ÷

  • ¿¼ÂÇ¿ÉÔÙÉúÄÜÔ´ºÍ´æ´¢ÏµÍ³
  • Ö§³ÖSunspecЭÒé
  • ͨ¹ýPVºÍ´æ´¢¼¯³ÉÌá¸ßÐÔÄÜ¿ÉÓÃÐÔ
  • ¿ÉÌṩ¶îÍâ¹â·ü³äµçºÍÀûÓÃ100%×ÔÉúÄÜÔ´½øÐгäµç

¿­·¢¡¤k8¹ú¼Ê,¿­·¢¹ÙÍø¸ºÔعÜÀí¿ØÖÆÆ÷

¿­·¢¡¤k8¹ú¼Ê,¿­·¢¹ÙÍø¸ºÔعÜÀí¿ØÖÆÆ÷£º²ð°üºÍ¼ÓÔØ¡£¿­·¢¡¤k8¹ú¼Ê,¿­·¢¹ÙÍø¸ºÔعÜÀí¿ØÖÆÆ÷£¬´øÓÐÔ¤ÖõĿ­·¢¡¤k8¹ú¼Ê,¿­·¢¹ÙÍø½ô´ÕÐÍ¿ØÖÆÆ÷100ÉϵĸºÔعÜÀíÓ¦ÓóÌÐò¡£´ËÍ⣬Ëü»¹¿ÉÁ¬½Óµ½ÍøÂçÔËÓªÉÌ»òÂ¥Óî¹ÜÀí²¿ÃÅ¡£

ÓÅÊÆ£º

  • Èí¼þÒÑ°²×°
  • ͨ¹ýWebä¯ÀÀÆ÷ÇáËɽøÐвÎÊýÉèÖÃ
  • ´ÓÏÂÀ­²Ëµ¥ÖÐÑ¡Ôñ¼æÈݵijäµçÕ¾ºÍ³¬¼¶³äµçÆ÷
  • ͨ¹ýÊý×ÖÁ¿ÊäÈë¿ÉÁé»îµ÷½Ú³äµç³¡

MM-22719_website_compact-controller-100_0751_9301_p1_2000x1125.jpg

¶ÀÁ¢ÓÚÖÆÔìÉÌ

¼æÈݳäµçÕ¾ºÍ±ÚºÐ

¿­·¢¡¤k8¹ú¼Ê,¿­·¢¹ÙÍøÓ¦ÓøºÔعÜÀí¼æÈÝÒÔϳäµçÕ¾ºÍ±ÚºÐ£ºABB¡¢ABL¡¢Alfen¡¢Compleo¡¢Delta¡¢Keba¡¢Mennekes¡¢SchneiderºÍTechnagon¡£´Ë´¦ÌṩÍêÕûÁбí£º

MM-484030_website-update-Integration-kompatible-Ladepunkte_charger_2000x1125.jpg

¼æÈÝÒDZí

¸ÃÈí¼þ½â¾ö·½°¸¼æÈÝÒÔϵç±í£ºABB¡¢Eastron¡¢EMU¡¢Hager¡¢Janitza¡¢Kostal¡¢PQ Plus¡¢Siemens¡¢Socomec¡¢TIPºÍ¿­·¢¡¤k8¹ú¼Ê,¿­·¢¹ÙÍø¡£Äú¿ÉÒÔÔÚ´ËÍêÕûÁбíÖÐÕÒµ½¸ü¶àÐÅÏ¢£º

MM-484030_website-update-Integration-kompatible-Ladepunkte_energymeter_2000x1125.jpg

¿­·¢¡¤k8¹ú¼Ê,¿­·¢¹ÙÍøµç¶¯½»Í¨

µç¶¯½»Í¨³ÉΪзçÏò

»ùÓÚ¡°ÂÌÉ«Æû³µÕþ²ß¡±µÄ¾­ÑéÓÅ»¯¿­·¢¡¤k8¹ú¼Ê,¿­·¢¹ÙÍøÓ¦ÓøºÔعÜÀí¡£

Ó¦ÓòúÆ·

ÄÜÔ´²âÁ¿¼¼Êõ

ÄÜÔ´¼à¿ØÊÇÌá¸ßÄÜÔ´·ÖÅäºÍ¹ý³ÌЧÂʵĻù´¡¡£ÎÒÃǵÄÅäÌ×ÄÜÔ´²âÁ¿²úÆ·¿ÉΪÄú¼õÉÙÄÜÔ´Êý¾ÝÊÕ¼¯·½ÃæµÄ¹¤×÷Á¿ºÍÏà¹ØÖ§³ö¡£µçÄܱíÊÊÓÃÓڼƷÑÏà¹Ø²âÁ¿µã¡£

¹¤ÒµÎÈѹµçԴϵÁÐ

ÎÞÂÛÊǼòµ¥Ó¦Óû¹ÊǾßÓиü¸ß¹¦ÂÊÐèÇóµÄ×Ô¶¯»¯Ó¦Ó㬿­·¢¡¤k8¹ú¼Ê,¿­·¢¹ÙÍøµÄ¸ßЧµçÔ´²úÆ·¶¼ÄÜʼÖÕΪÓû§Ìṩºã¶¨µçѹ¡£¿­·¢¡¤k8¹ú¼Ê,¿­·¢¹ÙÍøÌṩ²»Í£µçµçÔ´(UPS)¡¢»º³åÄ£¿é¡¢ÈßÓàÄ£¿éºÍ¸÷ÖÖµç×ӶϷÆ÷(ECB)£¬´Ù½øÕûÌåϵͳÎÞ·ìÉý¼¶¡£

MM-388432_GWA_IF-Categories_Power-Supplies-Systems_01_02_2000x2000.jpg

½»»»»ú

¿­·¢¡¤k8¹ú¼Ê,¿­·¢¹ÙÍø½»»»»úϵÁо߱¸³öÉ«µÄµçÆøºÍ»úеÌØÐÔ£¬È·±£ÄúµÄÒÔÌ«ÍøÍøÂç»ù´¡ÉèÊ©¾ß±¸¿ÉÀ©Õ¹ÄÜÁ¦¡£ÕâЩ¼á¹ÌÄÍÓõĽ»»»»úרΪ¹¤ÒµÓ¦ÓöøÉè¼Æ£¬ÇÒÍêÈ«·ûºÏIEEE 802.3¡¢IEEE 802.3uºÍIEEE 802.3ab±ê×¼¡£

mm-172328_switche_2000x1125.jpg

³£¼ûÎÊÌ⡪¡ª¹ØÓڵ綯½»Í¨
ºÍ³äµç»ù´¡ÉèÊ©¸ºÔعÜÀíµÄÎÊÌâºÍ½â´ð

ÀûÓóäµç»ù´¡ÉèÊ©µÄ¸ºÔعÜÀíϵͳ£¬¿ÉÒÔ½«µç¶¯½»Í¨À©Õ¹²¢¼¯³Éµ½µçÍøÖС£¶ÔÓڵ綯³µ³äµçµÄ¸ºÔعÜÀí£¬ÐèÒª¿ØÖƶà¸ö³äµçµãµÄ¹¦ÂÊ£¬ÒÔÓÅ»¯ÏÖÓеçÍøÁ¬½ÓµÄÀûÓÃÂÊ£¬¶øÎÞÐèÌá¸ß¶î¶¨¹¦ÂÊ£¬ÉõÖÁÎÞÐèÔÚµçÍø½Óµã°²×°ÐµĻ¥¸ÐÆ÷¡£Òò´Ë£¬ÔÚÓжà¸ö³äµçµãµÄµØ·½£¬Í¨³£ÐèÒª²ÉÓøºÔعÜÀíϵͳÒÔÕûºÏ³äµç»ù´¡ÉèÊ©£¬ÒòΪ¥Óͣ³µ³¡ºÍµØϳµ¿âͨ³£Ã»ÓÐÉè¼Æ´óÐ͵ĵçÁ¦´¢±¸ÉèÊ©¡£

Static load management is the simplest kind of load management system, where a preset static energy value is available to all loads. Static load management does not take any other consumers or generators into account.

An example of static load management for charging infrastructure:

Three charging stations are available with a total capacity of 22?kilowatt hours. If only one electric vehicle is charging at the three charging stations, it can be charged at the full?22 kilowatt hours. If two vehicles are connected, these 22?kilowatt hours are distributed equally among the two charging points.

Dynamic load management differs from static load management in one fundamental respect: The available energy is no longer static, but variable. In dynamic load management for charging infrastructure, the capacity is measured and dynamically distributed among the charging stations. For example, if the sun shining on solar power installations that feed into the grid, the total available charging power at the charging stations is increased to optimize utilization of the available electricity.

From the energy industry¡¯s point of view, load management is necessary in order to keep grids stable and ensure security of supply. In the area of e-mobility, this means supplying the growing charging infrastructure with the additional electricity it needs without overloading the grid interconnection points. This requires generation and consumption ¨C as well as storage, if applicable ¨C to be harmonized. But renewable energy from decentralized generators fluctuates. Therefore, it is important to use surplus energy in the grid through flexible loads. This is exactly where WAGO comes in. Load management regulates the flow of energy and controls all loads, energy storage systems and generators in the energy network.

In addition to the cost of energy consumed, industrial and commercial companies and large properties whose consumption exceeds 100?megawatt hours (MWh) must pay a so-called demand charge: the price that has to be paid if the set power limit is exceeded. For the demand charge, the maximum average power consumption is calculated at a quarter-hour intervals. Normally, the quarter hour with the highest mean value is applied to the whole year. For example, with a demand charge of 110?euros per kilowatt (kW), a load peak of 1,000?kW can lead to additional annual costs of 110,000?euros. With the integration of a charging infrastructure for e-mobility, an additional consumption factor is added. Therefore, intelligent load management for energy flows is extremely important, especially for preventing peak loads (so-called ¡°peak shaving¡±) in order to avoid additional costs.

Energy management is a higher-level system in which all load currents of consumers and generators are continuously measured, monitored and optimized. Energy management systems are used in intelligent networks such as smart grids, microgrids and nanogrids to improve energy efficiency. This includes real estate, industrial companies and even utilities. A fundamental goal is to minimize the consumption of auxiliary materials, additives and raw materials. Load management for charging infrastructure ensures a sensible distribution of existing loads within the energy management. So load management is only part of an overall energy management package ¨C albeit an important one.

¿­·¢¡¤k8¹ú¼Ê,¿­·¢¹ÙÍø